Removing and installing evaporator - AR83.30-P-5540E
MODEL 170, 202, 208, 210 with CODE (580) Air conditioning or, for USA, Tempmatic with CODE (581a) Automatic air conditioning
Other references
Change References
| 12.8.97 |
Safety note added |
|
|
  |
Removal, installation |
|
|
 |
Explosion hazard
when performing welding or brazing work on closed air conditioning. Poisoning hazard
from inhaling overheated refrigerant vapors. Injury hazard
from eye or skin contact with liquid refrigerant |
Never perform welding or brazing work on the closed air conditioning system or in its vicinity. Smoking and open flame is prohibited. Wear protective goggles and protective gloves, work only in well ventilated rooms. Perform repair work on air conditioning circuit only if system is discharged. |
AS83.00-Z-0001-01A |
 |
Action to be taken in the event air conditioning is damaged or leaks |
|
AH83.30-N-0004-01A |
 |
Protect air conditioning circuit and components from moisture during repair work |
All models with air conditioning |
AH83.30-N-0005-01A |
 |
Notes on handling R134a refrigerant |
All models with R134a refrigerant |
AH83.30-N-0003-01A |
| 1 |
Remove AC housing |
Model 170 |
AR83.30-P-5200G |
| |
|
Model 202 |
AR83.30-P-5200E |
| |
|
Models 208, 210 |
AR83.30-P-5200F |
| 2 |
Remove heat exchanger |
|
AR83.25-P-1100E |
| 3 |
Remove valve strip |
|
|
| 4 |
Disconnect vacuum lines from vacuum element (44) |
|
|
| 5 |
Separate blower housing (2) from air distribution housing (1), unclip 2 sliding clips (3) and 4 clips |
|
|
| 6 |
Unscrew screw (4) |
|
|
| 7 |
Remove gasket (6) |
|
|
| 8 |
Remove air distribution housing upper section (18 clips) |
|
|
| 9 |
Remove evaporator |
Clean air distribution housing bottom section
Installation:
Observe quantity of oil to be added when replacing evaporator |
*BF83.55-P-1004-01A |
| 10 |
Unscrew screws (5) remove expansion valve (82) |

Plug openings (parts kit), replace O-rings (moisten with compressor oil). When installing, ensure that sealing strips are seated properly |
BA83.30-P-1002-01A |
| 11 |
Replace receiver/drier |
Models 202, 208, 210 |
AR83.30-P-6520E |
| |
|
Model 170 |
AR83.30-P-6520G |
| 12 |
Reinstall in opposite order |
|
|
| 13 |
Switch on air conditioning and allow it to idle for approx. 4 minutes |
Set temperature dials to blue or automatic air conditioning to " Lo" Blower to max. |
|
| 14 |
Check air conditioning for proper function |
Air outlet temperature at center nozzle should not drop below +5 ° C, if necessary ↓ Perform diagnosis according to Diagnosis Manual |
|
| 15 |
Find leaky point in air conditioning circuit |
 |
*WE58.40-Z-1002-20A |

Air conditioning
| Number |
Designation |
Model 202 |
Model 210 |
Model 170 |
Model 208 |
| BA83.30-P-1002-01A |
Screw on expansion valve |
Nm |
8 |
8 |
8 |
8 |

A/C compressor
| Number |
Designation |
A/C compressor 7SB16 on models 140, 170, 202, 208, 210 |
| BF83.55-P-1004-01A |
Additional oil filling capacity when replacing evaporator |
Compressor oil |
cm3 |
40 |
| Specifications for service products |
Sheet |
BB00.40-P-0362-00A |

A/C compressor
| Number |
Designation |
A/C compressor ND6CA17 on model 202 |
| BF83.55-P-1004-01A |
Additional oil filling capacity when replacing evaporator |
Compressor oil |
cm3 |
40 |
| Specifications for service products |
Sheet |
BB00.40-P-0362-00A |
Workshop equipment
| WE58.40-Z-1002-20A |
Air conditioning leak detector |