Stationary heater (STH) diagnosis, troubleshooting - AD83.70-P-5001A
MODEL 129 as of 1.6.97 with CODE (228) stationary heater
| Stationary heater (STH) diagnosis, advanced information | AD83.70-P-2001A | ||
| Stationary heater unit, location of components | GF83.70-P-0006-03B | ||
| Troubleshooting | |||
| Complaint | Possible cause | Note | Remedy |
| It is not possible to start the stationary heater unit |
|
Charge battery | |
|
See Hand-Held Tester (HHT) | ||
|
AD83.70-P-6001-03A | ||
|
Check all actual values with HHT | ||
| Malfunction shut-down at start of heater operation with heater unit run-on (approx. 120 seconds) of combustion air blower (A6m2) and circulating pump (A6m1) without repeat start. |
|
Check all actual values with HHT | |
| Malfunction shut-down at start of heater operation with heater unit run-on (approx. 120 seconds) of combustion air blower (A6m2) and circulating pump (A6m1) after an unsuccessful repeat start initiated automatically. |
|
Check all actual values with HHT | |
| Combustion starts during the preglow time |
|
Allow heater unit to operate for 10 minutes | |
|
AD83.70-P-7000-02A | ||
| Vehicle heater blower does not operate at a coolant temperature > 30°C |
|
AD83.70-P-6001-09A | |
|
AD83.70-P-6001-08A | ||
| Stationary heater/heater booster unit (A6) does not switch to full load operation despite a requirement for heat |
|
Check all actual values with HHT | |
| Despite a requirement for heat, the stationary heater/heater booster unit (A6) goes into the combustion interval within approx. 10 minutes during trouble-free heater mode. |
|
Check coolant level, if necessary replenish and/ or bleed coolant circuit. | |
|
Check coolant lines for kinks and pinching | ||
|
AD83.70-P-6001-08A | ||
|
AD83.70-P-6001-09A | ||
|
Check all actual values with HHT | ||
| Heat output too low |
|
Increase temperature setting | |
|
Check combustion air inlet for contamination and clean if necessary Check coolant level and if necessary replenish and/ or bleed coolant circuit. | ||
|
Check coolant lines for kinks and pinching. | ||
|
Check function | ||
|
Check all actual values with HHT | ||
| Despite a reduced requirement for heat, stationary heater/heater booster unit (A6) is not switched to part load operation or to the combustion interval. |
|
Check all actual values with HHT | |
| Escape of combustion exhaust gases which are sooty or form dense smoke |
|
Check combustion air inlet for contamination and if necessary clean | |
|
|||
|
Check and adjust exhaust emissions value with HHT | ||
|
AD83.70-P-7000-01A | ||
|
Check all actual values with HHT | ||
| Gray/white combustion exhaust gases (white smoke) |
|
Check and adjust exhaust emissions value with HHT | |
| Loss of coolant Gray/white combustion exhaust gases (white smoke) Exhaust gas odor extremely sweet |
|
Check stationary heater/ heater booster unit (A6) for external leaks and if necessary replace heater unit. | |
| Loss of fuel or fuel odor |
|
Localize leakage point, check fuel metering pump, fuel supply lines, connections and stationary heater unit for fuel leaks and if necessary seal leakage point or replace component | |
| Heater operation cannot be terminated manually |
|
AD83.70-P-6001-03A | |
| It is not possible to test the stationary heater components with the HHT No communication between HHT and stationary heater/heater booster control module (A6n1) |
|
Check and if necessary replace AD83.70-P-6001-01A AD83.70-P-6001-02A |