SLOW ENGAGING AFTER OPERATING SELECTOR LEVER FROM N TO D POSITION (ET6A-EL, ET6AX-EL) DIAGNOSTIC PROCEDUREs
| Step | Inspection | Results | Action |
|---|---|---|---|
| 1 | VERIFY MALFUNCTION SYMPTOM
|
Yes | Symptom troubleshooting is completed. |
| No | Go to the next step. | ||
| 2 | VERIFY DTCs
|
Yes | Repair the malfunctioning location according to the applicable DTC troubleshooting. (See ON-BOARD DIAGNOSTIC SYSTEM DTC TABLE [TCM (ET6A-EL, ET6AX-EL) (US)] .) |
| No | Go to the next step. | ||
| 3 | PERFORM INITIAL LEARNING AND N TO D RANGE LEARNING
|
Yes | Complete the symptom troubleshooting. |
| No | Replace the automatic transaxle. (See AUTOMATIC TRANSAXLE REMOVAL/INSTALLATION [ET6A-EL (SKYACTIV-G 2.0, SKYACTIV-G 2.5) (US)] .) (See AUTOMATIC TRANSAXLE REMOVAL/INSTALLATION [ET6AX-EL (SKYACTIV-G 2.0, SKYACTIV-G 2.5 (US))] .) |