Diagnostic Procedure
DIAGNOSTIC PROCEDURE
| Step | Inspection | Action | |
|---|---|---|---|
| 1 | INSPECT CLUSTER SWITCH CONNECTOR CONDITION
|
Yes | Go to the next step. |
| No | Repair or replace the connector, then go to Step 6. | ||
| 2 | INSPECT CLUSTER SWITCH GROUND CIRCUIT FOR OPEN CIRCUIT
|
Yes | Go to the next step. |
| No | Refer to the wiring diagram and verify whether or not there is a common connector between cluster switch terminal C and body ground. If there is a common connector:
Go to Step 6. |
||
| 3 | INSPECT INSTRUMENT CLUSTER CONNECTOR CONDITION
|
Yes | Go to the next step. |
| No | Repair or replace the connector, then go to Step 6. | ||
| 4 | INSPECT CLUSTER SWITCH CIRCUIT FOR OPEN CIRCUIT
|
Yes | Go to the next step. |
| No | Refer to the wiring diagram and verify whether or not there is a common connector between instrument cluster terminal V and cluster switch terminal B. If there is a common connector:
|
||
| 5 | INSPECT CLUSTER SWITCH
|
Yes | Go to the next step. |
| No | Replace the cluster switch, then go to the next step. (See CLUSTER SWITCH REMOVAL/INSTALLATION .) |
||
| 6 | VERIFY THAT REPAIRS HAVE BEEN COMPLETED
|
Yes | Repeat the inspection from Step 1.
|
| No | Go to the next step. | ||
| 7 | VERIFY IF OTHER DTCs DISPLAYED
|
Yes | Repair the malfunctioning part according to the applicable DTC troubleshooting. (See DTC TABLE [INSTRUMENT CLUSTER] .) |
| No | DTC troubleshooting completed. | ||