Seat Weight Sensor Calibration [Two-Step Deployment Control System]
CAUTION:
- If any of the following work is performed, perform the seat weight sensor calibration using the M-MDS.
- Replacement with a new seat weight sensor
- Replacement with a new seat weight sensor control module
- Replacement with new passenger-side seat parts
- Disassembly of the passenger-side seat
- If any of the following work is performed, perform the seat weight sensor inspection using the M-MDS. (See SEAT WEIGHT SENSOR INSPECTION [TWO-STEP DEPLOYMENT CONTROL SYSTEM] .)
- Removal of the passenger-side seat
- Loosening and retightening of passenger's seat fixing bolts
- Or, the vehicle is involved in a collision
- Have two 20 kg {44 lb} weights ready to use.
- Connect the M-MDS (IDS) to the DLC-2.
- After the vehicle is identified, select the following items from the initialization screen of the IDS.
- Select "Body".
- Select "Restraints".
- Then, select item from the screen menu in the following order.
- Select "Passenger Seat Weight Sensor ReZero".
- Then, select item from the SWS Calibration screen menu in the following order.
- Select the "(1)-When you have replaced any SWS or SWS module, and/or any seat part except SWS."
- Perform calibration following the procedures on the M-MDS screen.