Step Inspection Action
1 PERFORM PCM DTC INSPECTION 
Yes Go to the applicable DTC inspection.
(See DTC TABLE [MZR 2.5] .)
(See DTC TABLE [MZI 3.7 V6] .)
No Go to the next step.
2 INSPECT FUSE 
  • Switch the ignition to off.
  • Disconnect the negative battery cable.
  • Remove and inspect the following fuses:
    • MAIN 125 A fuse
    • BTN 30 A fuse
    • ROOM 15 A fuse
    • IG KEY1 40 A fuse
    • METER IG 15 A fuse
  • Are there any malfunction?
Yes Replace the malfunctioning fuse, then go to Step 11.
No Go to the next step.
3 INSPECT BATTERY 
Yes Recharge or replace the battery, then go to Step 11.
(See BATTERY RECHARGING [MZR 2.5] .)
(See BATTERY RECHARGING [MZI 3.7 V6] .)
(See BATTERY REMOVAL/INSTALLATION [MZR 2.5] .)
(See BATTERY REMOVAL/INSTALLATION [MZI 3.7 V6] .)
No Go to the next step.
4 INSPECT GENERATOR 
Yes Replace the generator, then go to Step 11.
(See GENERATOR REMOVAL/INSTALLATION [MZR 2.5] .)
(See GENERATOR REMOVAL/INSTALLATION [MZI 3.7 V6] .)
No Go to the next step.
5 INSPECT IGNITION SWITCH CONNECTOR CONDITION 
  • Disconnect the ignition switch connector.
  • Inspect the connector for poor connection (such as damaged/pulled-out pins, and corrosion).
  • Is there any malfunction?
Yes Repair or replace the connector or terminal, then go to Step 11.
No Go to the next step.
6 INSPECT INSTRUMENT CLUSTER CONNECTOR CONDITION 
  • Disconnect the instrument cluster connector.
  • Inspect the connector for poor connection (such as damaged/pulled-out pins, and corrosion).
  • Is there any malfunction?
Yes Repair or replace the connector or terminal, then go to Step 11.
No Go to the next step.
7 INSPECT IGNITION SWITCH 
Yes Replace the ignition switch, then go to Step 11.
(See IGNITION SWITCH REMOVAL/INSTALLATION [WITHOUT ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM] .)
No Go to the next step.
8 INSPECT INSTRUMENT CLUSTER POWER SUPPLY CIRCUIT FOR SHORT TO GROUND OR OPEN CIRCUIT 
  • Install the fuses.
  • Reconnect the negative battery cable.
  • Switch the ignition to ON.
  • Measure the voltage between following terminals and body ground:
    • Instrument cluster terminal 2H (wiring harness-side)
    • Ignition switch terminal E (wiring harness-side)
  • Is the voltage B+  ?
Yes Go to the next step.
No Repair or replace the wiring harness for a possible short to ground or open circuit, then go to Step 11.
9 INSPECT INSTRUMENT CLUSTER POWER SUPPLY CIRCUIT FOR SHORT TO GROUND 
  • Switch the ignition to off.
  • Inspect for continuity between ignition switch terminal C (wiring harness-side) and body ground.
  • Is there continuity?
Yes Repair or replace the wiring harness for a possible short to ground, then go to Step 11.
No Go to the next step.
10 INSPECT INSTRUMENT CLUSTER POWER SUPPLY CIRCUIT FOR OPEN CIRCUIT 
  • Inspect for continuity between ignition switch terminal C (wiring harness-side) and instrument cluster terminal 2V (wiring harness-side).
  • Is there continuity?
Yes Go to the next step.
No Repair or replace the wiring harness for a possible open circuit, then go to the next step.
11 VERIFY TROUBLESHOOTING COMPLETED 
  • Switch the ignition to off.
  • Make sure reconnect the disconnected connectors.
  • Reconnect the negative battery cable.
  • Clear the DTC from the instrument cluster memory using the M-MDS.

    (See CLEARING DTC [INSTRUMENT CLUSTER] .)

  • Perform the instrument cluster DTC inspection using the M-MDS.

    (See DTC INSPECTION [INSTRUMENT CLUSTER] .)

  • Is the same DTC present?
Yes Replace the instrument cluster, then go to the next step.
(See INSTRUMENT CLUSTER REMOVAL/INSTALLATION .)
No Go to the next step.
12 VERIFY THAT NO OTHER DTCs ARE RECORDED 
  • Are any DTCs present?
Yes Go to the applicable DTC inspection.
(See DTC TABLE [INSTRUMENT CLUSTER] .)
No DTC troubleshooting completed.


Step Inspection Action
1 PERFORM PCM DTC INSPECTION 
Yes Go to the applicable DTC inspection.
(See DTC TABLE [MZR 2.5] .)
(See DTC TABLE [MZI 3.7 V6] .)
No Go to the next step.
2 INSPECT FUSE 
  • Switch the ignition to off.
  • Disconnect the negative battery cable.
  • Remove and inspect the following fuses:
    • MAIN 125 A fuse
    • BTN 30 A fuse
    • ROOM 15 A fuse
    • IG KEY1 40 A fuse
    • METER IG 15 A fuse
  • Are there any malfunction?
Yes Replace the malfunctioning fuse, then go to Step 11.
No Go to the next step.
3 INSPECT BATTERY 
Yes Recharge or replace the battery, then go to Step 11.
(See BATTERY RECHARGING [MZR 2.5] .)
(See BATTERY RECHARGING [MZI 3.7 V6] .)
(See BATTERY REMOVAL/INSTALLATION [MZR 2.5] .)
(See BATTERY REMOVAL/INSTALLATION [MZI 3.7 V6] .)
No Go to the next step.
4 INSPECT GENERATOR 
Yes Replace the generator, then go to Step 11.
(See GENERATOR REMOVAL/INSTALLATION [MZR 2.5] .)
(See GENERATOR REMOVAL/INSTALLATION [MZI 3.7 V6] .)
No Go to the next step.
5 INSPECT RELAY BLOCK CONNECTOR CONDITION 
  • Disconnect the relay block connector.
  • Inspect the connector for poor connection (such as damaged/pulled-out pins, and corrosion).
  • Is there any malfunction?
Yes Repair or replace the connector or terminal, then go to Step 11.
No Go to the next step.
6 INSPECT INSTRUMENT CLUSTER CONNECTOR CONDITION 
  • Disconnect the instrument cluster connector.
  • Inspect the connector for poor connection (such as damaged/pulled-out pins, and corrosion).
  • Is there any malfunction?
Yes Repair or replace the connector or terminal, then go to Step 11.
No Go to the next step.
7 INSPECT RELAY BLOCK 
Yes Replace the relay block, then go to Step 11.
(See RELAY BLOCK REMOVAL/INSTALLATION [WITH ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM] .)
No Go to the next step.
8 INSPECT INSTRUMENT CLUSTER POWER SUPPLY CIRCUIT FOR SHORT TO GROUND OR OPEN CIRCUIT 
  • Install the fuses.
  • Reconnect the negative battery cable.
  • Switch the ignition to ON.
  • Measure the voltage between following terminals and body ground:
    • Instrument cluster terminal 2H (wiring harness-side)
    • Relay block terminal 1A (wiring harness-side)
  • Is the voltage B+  ?
Yes Go to the next step.
No Repair or replace the wiring harness for a possible short to ground or open circuit, then go to Step 11.
9 INSPECT INSTRUMENT CLUSTER POWER SUPPLY CIRCUIT FOR SHORT TO GROUND 
  • Switch the ignition to off.
  • Inspect for continuity between relay block terminal 1B (wiring harness-side) and body ground.
  • Is there continuity?
Yes Repair or replace the wiring harness for a possible short to ground, then go to Step 11.
No Go to the next step.
10 INSPECT INSTRUMENT CLUSTER POWER SUPPLY CIRCUIT FOR OPEN CIRCUIT 
  • Inspect for continuity between relay block terminal 1B (wiring harness-side) and instrument cluster terminal 2V (wiring harness-side).
  • Is there continuity?
Yes Go to the next step.
No Repair or replace the wiring harness for a possible open circuit, then go to the next step.
11 VERIFY TROUBLESHOOTING COMPLETED 
  • Switch the ignition to off.
  • Make sure reconnect the disconnected connectors.
  • Reconnect the negative battery cable.
  • Clear the DTC from the instrument cluster memory using the M-MDS.

    (See CLEARING DTC [INSTRUMENT CLUSTER] .)

  • Perform the instrument cluster DTC inspection using the M-MDS.

    (See DTC INSPECTION [INSTRUMENT CLUSTER] .)

  • Is the same DTC present?
Yes Replace the instrument cluster, then go to the next step.
(See INSTRUMENT CLUSTER REMOVAL/INSTALLATION .)
No Go to the next step.
12 VERIFY THAT NO OTHER DTCs ARE RECORDED 
  • Are any DTCs present?
Yes Go to the applicable DTC inspection.
(See DTC TABLE [INSTRUMENT CLUSTER] .)
No DTC troubleshooting completed.