Diagnostic Procedure
WARNING: This page is about a different variant/trim than selected.
| STEP | INSPECTION | ACTION | |
|---|---|---|---|
| 1 | VERIFY FREEZE FRAME DATA HAS BEEN RECORDED
|
Yes | Go to the next step. |
| No | Record FREEZE FRAME DATA on the repair order, then go to the next step. | ||
| 2 | VERIFY RELATED REPAIR INFORMATION AVAILABILITY
|
Yes | Perform repair or diagnosis according to the available Service Bulletins.
|
| No | Go to the next step. | ||
| 3 | INSPECT OCV (LH) CONNECTOR FOR POOR CONNECTION
|
Yes | Repair or replace suspected part, then go to Step 10. |
| No | Go to the next step. | ||
| 4 | INSPECT OCV (LH)
|
Yes | Replace the OCV (LH), then go to Step 10. (See OIL CONTROL VALVE (OCV) REMOVAL/INSTALLATION .) |
| No | Go to the next step. | ||
| 5 | INSPECT OCV (LH) CIRCUIT FOR OPEN CIRCUIT
|
Yes | Go to the next step. |
| No | Repair or replace suspected part, then go to Step 10. | ||
| 6 | INSPECT OCV (LH) CIRCUIT FOR SHORT TO POWER SUPPLY
|
Yes | Repair or replace suspected part, then go to Step 10. |
| No | Go to the next step. | ||
| 7 | INSPECT OCV (LH) CIRCUIT FOR SHORT TO GROUND
|
Yes | Repair or replace suspected part, then go to Step 10. |
| No | Go to the next step. | ||
| 8 | INSPECT PCM CONNECTOR FOR POOR CONNECTION
|
Yes | Repair or replace suspected part, then go to Step 10. |
| No | Go to the next step. | ||
| 9 | INSPECT OCV (LH) CIRCUIT FOR OPEN CIRCUIT
|
Yes | Go to the next step. |
| No | Repair or replace suspected part, then go to the next step. | ||
| 10 | VERIFY TROUBLESHOOTING OF DTC P0020:00 HAS BEEN COMPLETED
|
Yes | Repeat the inspection from Step 1.
Go to the next step. |
| No | Go to the next step. | ||
| 11 | VERIFY AFTER REPAIR PROCEDURE
|
Yes | Go to the applicable DTC inspection. (See DTC TABLE .) |
| No | Troubleshooting completed. | ||