LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 2012 >> 6 i Touring >> Repair and Diagnosis >> External Pages >> Different car >> Section 637 (On-Board Diagnostic (Engine Control System L5) (5 Of 5)) >> DTC P2503:00 [LS] >> Diagnostic procedure

Diagnostic procedure

WARNING: This page is about a different car, the 2009 Mazda 6. However, it is still accessible from the selected car via links, so may be relevant.
STEP INSPECTION ACTION
1 VERIFY RELATED REPAIR INFORMATION AVAILABILITY 
  • Verify related Service Bulletins and/or on-line repair information availability
  • Is any related repair information available?
Yes Perform repair or diagnosis according to the available repair information
  • If the vehicle is not repaired, go to the next step.
No Go to the next step.
2 INSPECT DRIVE BELT CONDITION 
  • Verify that the drive belt auto tensioner indicator mark does not exceed limit
  • Is the front drive belt normal?
Yes Go to the next step.
No Replace or adjust drive belt, then go to Step 8. (See DRIVE BELT REMOVAL/INSTALLATION [L5] .)
3 INSPECT GENERATOR CONNECTOR CONDITION 
  • Switch the ignition to off
  • Disconnect the generator connector
  • Inspect for poor connection (such as damaged/pulled-out pins, corrosion)
  • Is there any malfunction?
Yes Repair or replace the terminal and/or connector, then go to Step 8
No Go to the next step.
4 INSPECT PCM CONNECTOR CONDITION 
  • Disconnect the PCM connector
  • Inspect for poor connection (such as damaged/pulled-out pins, corrosion)
  • Is there any malfunction?
Yes Repair or replace the terminal and/or connector, then go to Step 8.
No Go to the next step.
5 INSPECT GENERATOR CIRCUIT FOR SHORT TO GROUND 
  • Inspect for continuity between the following terminals and body ground
    • Generator terminal D (wiring harness-side)
    • Generator terminal P (wiring harness-side)
  • Is there continuity?
Yes Repair or replace the wiring harness for a possible short to ground, then go to Step 8.
No Go to the next step
6 INSPECT GENERATOR 
Yes Replace the generator, then go to Step 8.
(See GENERATOR REMOVAL/INSTALLATION [L5] .)
No Go to the next step
7 INSPECT GENERATOR CIRCUIT FOR OPEN CIRCUIT 
  • Inspect for continuity between the following terminals.
    • Generator terminal D (wiring harness-side) and PCM terminal 2AA (wiring harness-side)
    • Generator terminal P (wiring harness-side) and PCM terminal 2AF (wiring harness-side)
  • Is there continuity?
Yes Go to the next step.
No Repair or replace the wiring harness for a possible open circuit, then go to the next step.
8 VERIFY DTC TROUBLESHOOTING COMPLETED 
  • Make sure to reconnect all disconnected connectors.
  • Clear the DTC from the PCM memory using the M-MDS
  • Perform the KOER self test (See KOEO/KOER SELF TEST [L5] .)
  • Is the same DTC present?
Yes Replace the PCM, then go to the next step (See PCM REMOVAL/INSTALLATION [L5] .)
No Go to the next step
9 VERIFY AFTER REPAIR PROCEDURE 
Yes Go to the applicable DTC inspection. (See DTC TABLE [L5] .)
No DTC troubleshooting completed.