Manifold Gauge Set Connection
Courtesy of MAZDA MOTORS CORP.
- Turn both valves on the R-134a Manifold Gauge Set all the way to the left to close the low-pressure and high-pressure hoses to the center manifold and center hose.
Courtesy of MAZDA MOTORS CORP.
- Remove the A/C charging valve cap from the low pressure service gauge port valve.
Courtesy of MAZDA MOTORS CORP.
- Remove the A/C charging valve cap from the high pressure service gauge port valve.
Courtesy of MAZDA MOTORS CORP.
- Connect the R-134a manifold gauge set low-pressure hose and the R-134a low side quick disconnect to the low-pressure service gauge port valve.
Courtesy of MAZDA MOTORS CORP.
- Connect the R-134a manifold gauge set high-pressure hose and the R-134a high side quick disconnect to the high-pressure service gauge port valve.