Electronic Leak Detection

CAUTION:
  • Good ventilation is necessary in the area where electronic A/C leak testing is to be carried out. If the surrounding air is contaminated with refrigerant gas, the leak detector will indicate this gas all the time. Odors from other chemicals such as antifreeze, diesel fuel, disc brake cleaner, or other cleaning solvents can cause the same problem. A fan, even in a well-ventilated area, is very helpful in removing small traces of contamination from the air that might affect the leak detector.
Fig 1: Testing System Pressure
G01162141Courtesy of MAZDA MOTORS CORP.
NOTE:
  • System pressure should be between 413-551 kPa (60-80 psi) at 24°C (75°F) with the engine off.
  1. Leak test the refrigerant system using the Refrigerant Leak Detector. Follow instructions included with leak detector for handling and operation techniques.
    Fig 2: Testing System Pressure
    G01162142Courtesy of MAZDA MOTORS CORP.
  2. If a leak is found, recover the refrigerant and repair the system. For additional information, refer to DISCHARGING AND RECOVERY  .