Refrigerant Lines Description
WARNING: This page is about a different car, the 2002 Mazda B4000, 2002 Mazda B3000, and 2002 Mazda B2300. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:
Replacement of the receiver/drier is not required when repairing the air conditioning system except when there is physical evidence of system contamination from a failed A/C compressor or damage to the suction accumulator.
The condenser to evaporator line contains the high pressure liquid refrigerant upstream of the A/C evaporator core orifice.
The compressor manifold tube assembly is attached to the A/C compressor and has the following features:
- The upstream side contains low pressure refrigerant gas.
- The downstream side contains high pressure refrigerant gas and a fitting used to mount a serviceable high pressure A/C charge port valve.
- The downstream side also contains a fitting used to mount the A/C pressure cut-off switch. A long-travel Schrader-type valve stem core is installed in the fitting so that the A/C pressure cut-off switch can be removed without discharging the A/C system.