Pinpoint Test E : The Air Inlet Door Is Inoperative: Notes
Refer to Automatic Climate Control System for schematic and connector information.
Normal Operation and Fault Conditions
Air inlet door actuator, REFER to: Climate Control System - Vehicles With: Dual Automatic Temperature Control (DATC) - System Operation and Component Description
During an actuator calibration cycle, the HVAC control module drives the air inlet door until the door reaches both internal stops in the HVAC case. If the air inlet door is temporarily obstructed or binding during a calibration cycle, the HVAC control module may interpret this as the actual end of travel for the door. When this condition occurs and the HVAC control module commands the actuator to its end of travel, the air intake may not be from the expected source.
DTC Fault Trigger Conditions
| DTC | Description | Fault Trigger Conditions |
|---|---|---|
| B1083:00 | Recirculation Damper Motor: No Sub Type Information | This DTC sets when the HVAC control module senses a short to voltage, a short to ground, or an open when motor movement is commanded. |
Possible Sources
- Wiring, terminals or connectors
- Air inlet door actuator