Door Ajar Warning
- Door switches are open when doors are closed, and closed when door is open. When switch is closed, warning on instrument cluster is displayed.
- Open door, and disconnect wiring harness to door switch in door. Turn ignition on. No warning should be displayed on instrument cluster.
- Connect jumper wire between switch wiring harness terminal and ground. Warning should be displayed on instrument cluster. If warning is not displayed, check circuit No. 627 (Black/Orange wire) between instrument cluster connector C2-2 and switch for open.