LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2025 >> NX 350h >> Repair and Diagnosis >> Hybrid/Electric Powertrain >> Electric Motor Systems >> Hybrid Battery Control System - Service Information (2 Of 2) >> Frame Wire >> Installation [11/2021 - ] >> Procedure

Installation [11/2021 - ]: Procedure

  1. INSTALL FLOOR UNDER WIRE 
    WARNING:

    Be sure to wear insulated gloves.

    1. GTY1078690Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      Torque: 8.0 N*m (82 kgf*cm, 71 in.*lbf) 

    2. GTY1078623Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      1. Insert the HV floor under wire into the floor panel hole and engage the grommet.
      2. Install the 2 nuts.

        Torque: 8.0 N*m (82 kgf*cm, 71 in.*lbf) 

    3. GTY1077924Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      *a Waterproof Seal - -
      1. Install the HV floor under wire to the rear traction motor with transaxle assembly with the 2 bolts.

        Torque: 8.0 N*m (82 kgf*cm, 71 in.*lbf) 

        NOTE:
        • Make sure that the connector is fully engaged.
        • Do not damage the terminals, interlock connector or rear traction motor with transaxle assembly during installation.
        • Do not touch the waterproof seal or terminals of the connector.
        • Do not allow any foreign matter or water to enter the rear traction motor with transaxle assembly.
        • Although the connector may feel loose, this is not due to a malfunction.
      2. Engage the clamp.
      3. Install the 2 bolts.

        Torque: 8.0 N*m (82 kgf*cm, 71 in.*lbf) 

      4. Engage the clamp.
    4. GTY1078707Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      Torque: 8.0 N*m (82 kgf*cm, 71 in.*lbf) 

  2. INSTALL NO. 1 FLOOR UNDER COVER 

    Refer to PROCEDURE - Step 24 [11/2021 - 03/2023] , or refer to PROCEDURE - Step 24 [03/2023 - ]

  3. INSTALL FUEL TANK SUB-ASSEMBLY 

    Refer to INSTALLATION [11/2021 - ]

  4. INSTALL FRONT LOWER NO. 1 FLOOR HEAT INSULATOR 

    Torque: 4.9 N*m (50 kgf*cm, 43 in.*lbf) 

  5. INSTALL FRONT NO. 2 FLOOR HEAT INSULATOR 

    Torque: 4.9 N*m (50 kgf*cm, 43 in.*lbf) 

  6. INSTALL EXHAUST MANIFOLD 

    Refer to INSTALLATION [11/2021 - 03/2022] , or refer to INSTALLATION [03/2022 - ]

  7. INSTALL FRONT EXHAUST PIPE ASSEMBLY 

    Refer to INSTALLATION [11/2021 - ]

  8. INSTALL FRONT FLOOR COVER RH 

    Refer to PROCEDURE - Step 29 [11/2021 - 03/2024] , or refer to PROCEDURE - Step 27 [03/2024 - ]

  9. CONNECT FLOOR UNDER WIRE 
    WARNING:

    Be sure to wear insulated gloves.

    NOTE:

    Make sure that the connectors are connected securely.

    Torque: 7.6 N*m (77 kgf*cm, 67 in.*lbf) 

  10. INSTALL NO. 1 HV BATTERY COVER PANEL RH 

    Refer to PROCEDURE - Step 10

  11. INSTALL DECK TRIM SIDE PANEL ASSEMBLY RH 
    Refer to PROCEDURE - Step 24
  12. INSTALL NO. 1 LUGGAGE COMPARTMENT TRIM HOOK 
  13. INSTALL LUGGAGE HOLD BELT STRIKER ASSEMBLY 
  14. INSTALL ROPE HOOK ASSEMBLY 

    Refer to PROCEDURE - Step 27

  15. INSTALL REAR SEAT SIDE GARNISH RH 
  16. INSTALL NO. 1 SIDE TRIM BASE COVER RH 
  17. INSTALL REAR DOOR OPENING TRIM WEATHERSTRIP RH 
  18. INSTALL REAR FLOOR FINISH PLATE 
  19. INSTALL REAR SEAT CUSHION LEG SUB-ASSEMBLY 
    See step  4
  20. INSTALL BATTERY SERVICE COVER BOARD 

    See step  5

  21. INSTALL NO. 3 BATTERY SERVICE COVER BOARD 

    See step  6

  22. CONNECT REAR DOOR SCUFF PLATE LH 
  23. INSTALL NO. 2 BATTERY SERVICE COVER BOARD 
  24. INSTALL REAR DOOR SCUFF PLATE RH 
  25. INSTALL DECK FLOOR BOX RH 
  26. INSTALL JUNCTION BLOCK SERVICE COVER 
  27. INSTALL REAR FLOOR BOARD REAR RH 
  28. INSTALL REAR DECK FLOOR BOX 
  29. INSTALL REAR SEAT ASSEMBLY 
  30. CONNECT FLOOR UNDER WIRE 
    Refer to PROCEDURE - Step 16
  31. CONNECT ENGINE ROOM MAIN WIRE 
    WARNING:

    Be sure to wear insulated gloves.

    NOTE:
    • Do not touch the waterproof seal or terminals of the connectors.
    • To prevent damage due to static electricity, do not touch the terminals of the disconnected connectors.
    • Do not damage the terminals, connector housing or inverter with converter assembly when connecting the connectors.
    • Do not allow any foreign matter or water to enter the inverter with converter assembly.
  32. INSTALL NO. 2 INVERTER PROTECTOR 

    Refer to PROCEDURE - Step 18

  33. INSTALL SERVICE PLUG GRIP 

    See step  1

  34. PERFORM INITIALIZATION 

    Refer to WORK PROCEDURE [11/2021 - 03/2023] , or refer to WORK PROCEDURE [03/2023 - 03/2024] , or refer to WORK PROCEDURE [03/2024 - ]