Removal [08/2023 - ]: Procedure
- RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM
See step 1
- REMOVE SERVICE PLUG GRIP
Refer to REMOVAL [10/2022 - ]
- REMOVE NO. 1 ENGINE COVER SUB-ASSEMBLY
Refer to PROCEDURE - Step 22 - REMOVE AIR CLEANER ASSEMBLY WITH NO. 1 AIR CLEANER HOSE
Refer to PROCEDURE - Step 10
- REMOVE AIR CLEANER HOSE ASSEMBLY
Refer to PROCEDURE - Step 11
- REMOVE BATTERY COVER LOCK STRIKER
Refer to PROCEDURE - Step 16 - REMOVE INVERTER TERMINAL COVER
Refer to PROCEDURE - Step 17 - CHECK TERMINAL VOLTAGE
Refer to PROCEDURE - Step 18 - REMOVE INVERTER TERMINAL GASKET
Refer to PROCEDURE - Step 32 - INSTALL INVERTER TERMINAL COVER
Refer to PROCEDURE - Step 19 - INSTALL BATTERY COVER LOCK STRIKER
Refer to PROCEDURE - Step 10 - INSTALL AIR CLEANER HOSE ASSEMBLY
Refer to PROCEDURE - Step 19 - INSTALL AIR CLEANER ASSEMBLY WITH NO. 1 AIR CLEANER HOSE
Refer to PROCEDURE - Step 20 - INSTALL NO. 1 ENGINE COVER SUB-ASSEMBLY
Refer to PROCEDURE - Step 56 - REMOVE RADIATOR ASSEMBLY
Refer to REMOVAL [10/2022 - ]
- DISCONNECT SUCTION HOSE SUB-ASSEMBLY
- DISCONNECT DISCHARGE HOSE SUB-ASSEMBLY
- REMOVE COMPRESSOR WITH MOTOR ASSEMBLY
*a Connector (A) *b Connector (B) *c Green-colored Lock - - Slide - - - Slide the green-colored lock of the connector (A) as shown in the illustration to release it and disconnect the connector.WARNING:
Make sure to wear insulated gloves.
NOTE:Insulate the disconnected terminals and connector (A) with insulating tape.
- Disconnect the connector (B).
- Slide the green-colored lock of the connector (A) as shown in the illustration to release it and disconnect the connector.
- for Type A:
- Remove the bolt and 2 nuts.
- Using an E8 "TORX" socket wrench, remove the 2 stud bolts and compressor with motor assembly.
- for Type B:
- Remove the 3 bolts and compressor with motor assembly.