Removal [08/2021 - 09/2022]: Procedure
- RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM
Refer to PROCEDURE - Step 1
- REMOVE SERVICE PLUG GRIP
Refer to REMOVAL [08/2021 - 09/2022]
- CHECK TERMINAL VOLTAGE
- Disconnect the engine room main wire.
Refer to PROCEDURE - Step 3
- Remove the connector cover assembly.
Refer to PROCEDURE - Step 10
- Check the terminal voltage.
Refer to PROCEDURE - Step 11
- Install the connector cover assembly.
Refer to PROCEDURE - Step 6
- Connect the engine room main wire.
Refer to PROCEDURE - Step 18
- Disconnect the engine room main wire.
- REMOVE RADIATOR ASSEMBLY
Refer to REMOVAL [08/2021 - 09/2022]
- DISCONNECT SUCTION HOSE
- DISCONNECT NO. 1 COOLER REFRIGERANT DISCHARGE HOSE
- Remove the bolt and disconnect the No. 1 cooler refrigerant discharge hose from the compressor with motor assembly.
- Remove the O-ring from the No. 1 cooler refrigerant discharge hose.NOTE:
Seal the openings of the disconnected parts using vinyl tape to prevent moisture and foreign matter from entering them.
- Remove the bolt and disconnect the No. 1 cooler refrigerant discharge hose from the compressor with motor assembly.
- REMOVE COMPRESSOR WITH MOTOR ASSEMBLY
- Using a screwdriver, slide the green-colored lock of the connector (A) as shown in the illustration to release it and disconnect the connector.
*a Connector (A) *b Connector (B) *c Green-colored Lock Slide WARNING:Make sure to wear insulated gloves.
NOTE:Insulate the disconnected terminals and connector with insulating tape.
- Disconnect the connector (B).
- Remove the bolt and 2 nuts.
Bolt Nut - Using an E8 "TORX" socket wrench, remove the 2 stud bolts and compressor with motor assembly.
- Using a screwdriver, slide the green-colored lock of the connector (A) as shown in the illustration to release it and disconnect the connector.