DTC P0C76-523: Hybrid Battery System Discharge Time Too Long: Procedure
- CHECK DTC OUTPUT (HV)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Select the following menu items: Powertrain / Hybrid Control / Trouble Codes.
- Check if DTCs are output.
Result
Result Proceed to P0C76-523 only is output. A Any of the following DTCs are also output. B DTC No. Relevant Diagnosis P0A1A-151, 155, 156, 200, 201, 658, 659, 791, 792, 793 Generator Control Module P0A1B-163, 164, 168, 192, 193, 511, 512, 661, 786, 788, 794, 795, 796 Drive Motor "A" Control Module P0A3F-243 Drive Motor "A" Position Sensor Circuit P0A40-500 Drive Motor "A" Position Sensor Circuit Range / Performance P0A41-245 Drive Motor "A" Position Sensor Circuit Low P0A4B-253 Generator Position Sensor Circuit P0A4C-513 Generator Position Sensor Circuit Range / Performance P0A4D-255 Generator Position Sensor Circuit Low P0A78-113, 121, 266, 267, 279, 282, 284, 286, 287, 306, 503, 504, 505, 506 Drive Motor "A" Inverter Performance P0A7A-122, 322, 324, 325, 344, 517, 518 Generator Inverter Performance P0A90-509 Drive Motor "A" Performance P0A92-521 Hybrid Generator Performance P0A94-442 DC / DC Converter Performance P0ADC-226 Hybrid Battery Positive Contactor Control Circuit High P0AE0-228 Hybrid Battery Negative Contactor Control Circuit High P3240-443 DC/DC Converter Control Circuit
B → See step 2
A → See step 3
- GO TO DTC CHART. Refer to DIAGNOSTIC TROUBLE CODE CHART
- REPLACE INVERTER WITH CONVERTER ASSEMBLY. Refer to COMPONENTS