Heated Oxygen Sensor DATALOGGER Signals
WARNING: This page is about a different car, the 2018 Land Rover Range Rover, 2017 Land Rover Range Rover, 2016 Land Rover Range Rover, 2014 Land Rover Range Rover, and 2013 Land Rover Range Rover. However, it is still accessible from the selected car via links, so may be relevant.
| PID | DESCRIPTION | ACTION |
|---|---|---|
| BANK 1 | ||
| Datalogger signal for Heated Oxygen Sensor (HO2S) - Pre catalyst - Bank 1 sensor 1 | ||
| 0x03A1 | Oxygen Sensor (O2S) Heater Duty Cycle Bank 1 Sensor 1 | Using the manufacturer approved diagnostic system check datalogger signal. The signal is a duty cycle displayed in % varying between limits |
| 0xF434 | Oxygen Sensor Current Bank 1 sensor 1 | Using the manufacturer approved diagnostic system check datalogger signal. The signal is displayed in mA varying between limits |
| Datalogger signal for Heated Oxygen Sensor (HO2S) - Mid catalyst - Bank 1 sensor 2 | ||
| 0x03A2 | Oxygen Sensor (O2S) Heater Duty Cycle Bank 1 Sensor 2 | Using the manufacturer approved diagnostic system check datalogger signal. The signal is a pulse width modulated signal digital output operating between 0 and 1 |
| 0xF415 | Oxygen Sensor Output Voltage Bank 1 - sensor 2 | Using the manufacturer approved diagnostic system check datalogger signal. The signal is displayed in volts varying between limits |
| Datalogger signal for Heated Oxygen Sensor (HO2S) - Post catalyst - Bank 1 sensor 3 | ||
| 0x03A3 | Oxygen sensor heater duty cycle - Bank 1 sensor 3 | Using the manufacturer approved diagnostic system check datalogger signal. The signal is a pulse width modulated signal digital output operating between 0 and 1 |
| 0xF416 | Oxygen Sensor Output Voltage Bank 1 - sensor 3 | Using the manufacturer approved diagnostic system check datalogger signal. The signal is displayed in volts varying between limits |
| BANK 2 | ||
| Datalogger signal for Heated Oxygen Sensor (HO2S) - Pre catalyst - Bank 2 sensor 1 | ||
| 0x03A4 | Oxygen Sensor (O2S) Heater Duty Cycle Bank 2 Sensor 1 | Using the manufacturer approved diagnostic system check datalogger signal. The signal is a duty cycle displayed in % varying between limits |
| 0xF438 | Oxygen Sensor Current Bank 2 sensor 1 | Using the manufacturer approved diagnostic system check datalogger signal. The signal is displayed in mA varying between limits |
| Datalogger signal for Heated Oxygen Sensor (HO2S) - Mid catalyst - Bank 2 sensor 2 | ||
| 0x03A5 | Oxygen Sensor (O2S) Heater Duty Cycle Bank 2 Sensor 2 | Using the manufacturer approved diagnostic system check datalogger signal. The signal is a pulse width modulated signal digital output operating between 0 and 1 |
| 0xF419 | Oxygen Sensor Output Voltage Bank 2 - sensor 2 | Using the manufacturer approved diagnostic system check datalogger signal. The signal is displayed in volts varying between limits |
| Heated Oxygen Sensor (HO2S) - Post catalyst - Bank 2 sensor 3 | ||
| 0x03A6 | Oxygen sensor heater duty cycle - Bank 2 sensor 3 | Using the manufacturer approved diagnostic system check datalogger signal. The signal is a pulse width modulated signal digital output operating between 0 and 1 |
| 0xF41A | Oxygen Sensor Output Voltage Bank 2 - sensor 3 | Using the manufacturer approved diagnostic system check datalogger signal. The signal is displayed in volts varying between limits |