C-CAN Inspection
| Inspection Condition | (+) Probe | (-) Probe | Specification | ||
|---|---|---|---|---|---|
| Connector | Terminal | Connector | Terminal | ||
|
MDPS unit connector | 7 (C-CAN high) | MDPS unit connector | 8 (C-CAN low) | Approx. 60Ω |
| ICU (component side) | 29 (C-CAN high) | ICU (component side) | 30 (C-CAN low) | Approx. 120Ω | |
| MDPS unit connector | 7 (C-CAN high) | ICU connector | 9 (C-CAN high) | Approx. below 1Ω | |
| MDPS unit connector | 8 (C-CAN low) | ICU connector | 10 (C-CAN low) | Approx. below 1Ω | |
Good
- Go to "P-CAN INSPECTION " procedure.
No Good
- Repair open or short in circuit and then Go to "VERIFICATION OF REPAIR " procedure.