P-CAN Inspection
| Inspection Condition | (+) Probe | (-) Probe | Specification | ||
|---|---|---|---|---|---|
| Connector | Terminal | Connector | Terminal | ||
|
ICU (component side) | 22 (P-CAN high) | ICU (component side) | 23 (P-CAN low) | Approx. 120Ω |
| ECM (component side) | 77 (P-CAN high) | ECM (component side) | 60 (P-CAN low) | Approx. 120Ω | |
| ICU connector | 22 (P-CAN high) | ECM (component side) | 77 (P-CAN high) | Approx. below 1Ω | |
| ICU connector | 23 (P-CAN low) | ECM (component side) | 60 (P-CAN low) | Approx. below 1Ω | |
Good
- Fault might be intermittent and caused either by poor contact in connectors or wiring harness, or it has been repaired and control module memory is not cleared yet. Thoroughly check terminal of battery, all connectors (and connections) for looseness, bending, corrosion, contamination, deterioration, and/or damage.
- Repair or replace as necessary and then Go to "VERIFICATION OF REPAIR " procedure.
No Good
- Carefully re-do this troubleshooting guide steps.