Charging-related Vehicle Condition Inspection
- Refer to the table to check the charging status.
Type Conditions Inspection Scheduled charging - [AVN] Scheduled charging cancelled
- [AVN] Reservation is deleted from the "Charging Schedule Setting" menu (Only available within 3 minutes after connecting the charging cable)
- [AVN] Scheduled charging time is up
- Cancel the scheduled charging via the AVN and charge the vehicle.
Battery setting when charging completed - [AVN] The after-regular-charging battery setting is greater than the current high voltage battery state of charge (SOC)
- Change the after-regular-charging battery setting to 100% via the AVN. Then, charge the vehicle.
Gear lever position - "P" position
- Put the gear in "P" and charge the vehicle.
Auxiliary battery - Normal
- Charge the vehicle when the auxiliary battery is normal.
Good
- Explain the regular charging conditions to the customer.
No Good
- Go to "CHARGING SYSTEM INSULATION RESISTANCE INSPECTION " procedure.