DTC Information: DTC Detecting Condition

Item Detecting Condition Possible Cause
DTC Strategy
  • Check the output current
  • High voltage cable
  • OBC ECU
Enable Condition
  • Charging connector connected
  • Slow charging mode (EVSE ready "ON")
  • Auxiliary battery voltage: 9 to 16V
  • S2 switch "ON"
Threshold Value
  • Output current is greater than 17A
Diagnostic Time
  • 10 times or 30s
MIL On Condition
  • ON
Service Lamp On Condition
  • ON