LEMON Manuals: Even more car manuals for everyone
Home >> Kia >> 2023 >> Sorento Plug-In Hybrid SX Prestige >> Repair and Diagnosis >> Hybrid/Electric Powertrain >> Testing and Diagnosis >> On Board Charger Diagnosis (PHEV) (2 Of 2) >> DTC P0D9F-1C: Battery Charger Coupler Lock Position Sensor Circuit Range/Performance >> DTC Information >> DTC Detecting Condition

DTC Information: DTC Detecting Condition

Item Detecting Condition Possible Cause
DTC Strategy
  • Check on the inlet lock actuator
  • Inlet lock actuator
  • Poor contact of connector (inlet to OBC)
Detecting Condition
  • Charging connector connected and ignition "ON"
  • Auxiliary battery voltage: 9 to 16V
  • No inlet lock sensing circuit performance error/high voltage/low voltage
Threshold Value
  • Check inlet lock actuator position sensing state "fault" in current data with KDS
  • When the reference voltage of the position sensor differs by more than ±0.4V when the locking device is open/closed
Detecting Time
  • 1s
MIL On Condition
  • None
Service Lamp On Condition
  • None