| DTC Strategy |
- Check on the inlet lock actuator is not operating
|
- Inlet lock actuator
- Poor contact of connector or signal circuit of inlet lock control
|
| Case 1 |
Detecting Condition |
- Charging connector connected and ignition "ON"
- Auxiliary battery voltage: 9 to 16V
- No inlet lock sensing circuit performance error/high voltage/low voltage
- No inlet lock control circuit error
|
| Threshold Value |
- Check inlet lock actuator operation state "fail" in current data with KDS
- Check OBC1 CAN signal "OBC_InletFailSta=1"
- Visually check that the locking device is not locked
|
| Detecting Time |
|
| Case 2 |
Detecting Condition |
- Charging connector connected and ignition "ON"
- No inlet lock control circuit error
- Auxiliary battery voltage: 9 to 16V
|
| Threshold Value |
- Inlet relay driver unlock input signal and output signal mismatch
|
| Detecting Time |
|
| MIL On Condition |
|
| Service Lamp On Condition |
|