Circuit Inspection
| Charge Terminal Inspection | |||||
|---|---|---|---|---|---|
| Inspection Condition | (+) Probe | (-) Probe | Specification | ||
| Connector | Terminal | Connector | Terminal | ||
|
FB11 connector | 8 (signal) | Chassis ground | - | 5V |
|
FB11 connector | 9 (ground) | Chassis ground | - | Approx. 1 to 1.7V (lock) |
| Approx. 2.7 to 3.55V (unlock) | |||||
|
FB11 connector | 8 (signal) | OBC connector | 6 (signal) | Approx. below 1Ω |
| FB11 connector | 9 (ground) | OBC connector | 14 (ground) | Approx. below 1Ω | |
|
FB11 connector | 11 (unlock) | Chassis ground | - | B+ |
| FB11 connector | 10 (lock) | Chassis ground | - | B+ | |
| OBC connector | 31 (unlock) | Chassis ground | - | B+ | |
| OBC connector | 23 (lock) | Chassis ground | - | B+ | |
Good
- Carefully re-do this troubleshooting guide steps.
- If no problems were found with the circuits or connectors, replace the OBC and then Go to "Verification Of Repair " procedure.
No Good
- Repair as necessary and then Go to "Verification Of Repair " procedure.
CAUTION:
■ In case of replaced or repaired OBC, Replenish the cooling water and the electric water pump (EWP) is driven by KDS to circulate the cooling water.