Pinpoint Test B: Buckle/Retractor Pre TENSIONER Diagnostic
WARNING: This page is about a different car, the 2018 Jaguar XE and 2017 Jaguar XE. However, it is still accessible from the selected car via links, so may be relevant.
- B1: DIAGNOSTIC PROCEDURE
- Prior to any work on the SRS system the vehicle battery must be disconnected
- Please wait for 120 seconds to allow the airbag deployment energy reserve to dissipate
- Check routing and condition of harness along buckle pre tensioner tube
- Ensure harness is in good condition with no damage
- Ensure harness is securely routed
- Reconnect the vehicle battery
- Clear the DTC, cycle the ignition state off/on wait 30 seconds and re-test
- To confirm repair. Whilst sitting in seat, retest as follows:
- Seat fully up - move fully backwards and forwards
- Seat fully down - move fully backwards and forwards
Is the warning lamp illuminated?
- Yes : GO to Pinpoint Test C .
- No : No further action required