Pinpoint Test A: Buckle/Retractor Pre TENSIONER Diagnostic
WARNING: This page is about a different car, the 2018 Jaguar XE and 2017 Jaguar XE. However, it is still accessible from the selected car via links, so may be relevant.
- A1: DIAGNOSTIC PROCEDURE
- Prior to any work on the SRS system the vehicle battery must be disconnected.
- Please wait for 120 seconds to allow the airbag deployment energy reserve to dissipate
- Check location of harness fly-lead ensuring there is no risk snagging and sufficient strain relief during full seat travel
- Disconnect under seat buckle pre tensioner connectors
- Check connector for water ingress or signs of corrosion (white/green residue)
- Check for debris in female connector and remove as required
- Check for debris in male harness end connector and remove
- Check that male connector pins are secure and in good condition
- Check that all connector terminals are clean secure and in good condition
- Reconnect the connector
Note: An audible click should be heard confirming security
- Check actuator harness fly-lead is connected and correctly routed
- Reconnect the vehicle battery
- Clear the DTC, cycle the ignition state off/on wait 30 seconds and retest
- To confirm repair. Whilst sitting in seat, retest as follows:
- Seat fully up - move fully backwards and forwards
- Seat fully down - move fully backwards and forwards
Is the warning lamp illuminated?
- Yes : GO to Pinpoint Test B .
- No : No further action required