DTC Diagnosis Procedure
NOTE:
The Signal Tech II Tool [- (NI-50190)] can be used to perform the following functions: Refer to the Signal Tech II User Guide for additional information.
- Activate and display TPMS sensor IDs
- Display tire pressure reported by the TPMS sensor
- Read TPMS DTCs
- Register TPMS sensor IDs
- CHECK FUSES
- Check that the following fuses are not blown:
Terminal No. Signal name Fuse No. Capacity 161 BCM power supply 2 5 A 167 Power door lock 1 power supply 11 20 A 168 Flashers power supply 14 10 A 169 Stop lamp power supply 49 10 A 175 Power door lock 2 power supply 12 15 A 176 Windshield washer power supply 10 15 A 95 BCM power supply 38 5 A
Is the fuse blown?
YES>>
Replace the blown fuse after repairing the affected circuit.
NO>>
GO TO 2.
- Check that the following fuses are not blown:
- CHECK POWER SUPPLY CIRCUITS
Is the inspection result normal?
YES>>
GO TO 3.
NO>>
Repair or replace harness or connectors.
- CHECK GROUND CIRCUIT
- Check continuity between BCM harness connector and ground.
BCM - Continuity Connector Terminal M20 170 Ground Yes 171
Is the inspection result normal?
YES>>
GO TO 4.
NO>>
Repair or replace harness or connectors.
- Check continuity between BCM harness connector and ground.
- CHECK PUSH-BUTTON IGNITION SWITCH OUTPUT SIGNAL
-
- Ignition switch OFF.
- Connect BCM connector.
- Disconnect push-button ignition switch connector and IPDM E/R connector E120.
- Check voltage between push-button ignition switch harness connector and ground.
(+) (-) Voltage(Approx.) Push-button ignition switch Connector Terminal M17 5 Ground Battery voltage
Is the inspection result normal?
YES>>
GO TO 6.
NO>>
GO TO 5.
-
- CHECK PUSH-BUTTON IGNITION SWITCH CIRCUIT (BCM)
-
- Disconnect BCM connector.
- Check continuity between BCM harness connector and push-button ignition switch harness connector.
BCM Push-button ignition switch Continuity Connector Terminal Connector Terminal M304 89 M17 5 Yes - Check continuity between BCM harness connector and ground.
BCM - Continuity Connector Terminal M304 89 Ground No
Is the inspection result normal?
YES>>
Replace BCM. Refer to Removal and Installation .
NO>>
Repair or replace harness or connectors.
-
- CHECK PUSH-BUTTON IGNITION SWITCH CIRCUIT (IPDM E/R)
-
- Disconnect BCM connector.
- Check continuity between IPDM E/R harness connector and BCM harness connector.
IPDM E/R BCM Continuity Connector Terminal Connector Terminal E120 32 M304 89 Yes - Check continuity between IPDM E/R harness connector and ground.
IPDM E/R - Continuity Connector Terminal E120 32 Ground No
Is the inspection result normal?
YES>>
Replace IPDM E/R. Refer to Removal and Installation .
NO>>
Repair or replace harness or connectors.
-