DTC Diagnosis Procedure
- CHECK AMBIENT SENSOR POWER SUPPLY
Is the inspection result normal?
YES>>
GO TO 2.
NO>>
GO TO 4.
- CHECK AMBIENT SENSOR GROUND CIRCUIT
Is the inspection result normal?
YES>>
GO TO 3.
NO>>
Repair or replace harness or connector.
- CHECK AMBIENT SENSOR
- Check ambient sensor. Refer to Component Inspection .
Is the inspection result normal?
YES>>
Replace combination meter. Refer to Removal and Installation .
NO>>
Replace ambient sensor. Refer to Removal and Installation .
- CHECK AMBIENT SENSOR POWER SUPPLY CIRCUIT FOR OPEN
Is the inspection result normal?
YES>>
GO TO 5.
NO>>
Repair or replace harness or connector.
- CHECK AMBIENT SENSOR POWER SUPPLY CIRCUIT FOR GROUND SHORT
- Check continuity between ambient sensor harness connector and ground.
Ambient sensor - Continuity Connector Terminal E76 1 Ground No
Is the inspection result normal?
YES>>
GO TO 6.
NO>>
Repair or replace harness or connector.
- Check continuity between ambient sensor harness connector and ground.
- CHECK AMBIENT SENSOR POWER SUPPLY CIRCUIT FOR POWER SHORT
Is the inspection result normal?
YES>>
Replace combination meter. Refer to Removal and Installation .
NO>>
Repair or replace harness or connector.