Diagnosis Procedure
- CHECK CONNECTOR
-
- Ignition switch OFF.
- Check the ABS actuator and electric unit (control unit) harness connector for disconnection or looseness.
Is the inspection result normal?
YES>>
GO TO 3.
NO>>
Repair / replace harness or connector, securely lock the connector, and GO TO 2.
-
- PERFORM SELF DIAGNOSTIC RESULT
CONSULT
- Ignition switch OFF.NOTE:
Wait at least 10 seconds after placing ignition switch OFF.
- Start the engine.NOTE:
Wait at least 10 seconds after starting the engine.
- Select "Self Diagnostic Result" mode of "ABS".
- Ignition switch OFF.
Is DTC "C112E-4B" detected?
YES>>
GO TO 3.
NO>>
Inspection End.
- CHECK ABS ACTUATOR AND ELECTRIC UNIT (CONTROL UNIT) POWER SUPPLY AND GROUND CIRCUIT
- Check the ABS actuator and electric unit (control unit) power supply and ground circuits. Refer to Diagnosis Procedure .
Is the inspection result normal?
YES>>
GO TO 4.
NO>>
Repair / replace harness, connector, fuse, or fusible link.
- CHECK TERMINAL
- Check the ABS actuator and electric unit (control unit) pin terminals for damage or loose connection with harness connector.
Is the inspection result normal?
YES>>
Replace the ABS actuator and electric unit (control unit). Refer to Removal and Installation .
NO>>
Repair / replace harness, connector, or terminal.