3CH Can Gateway: Description
For work procedure, refer to Work Procedure .
BEFORE REPLACEMENT
When replacing 3CH CAN gateway, save or print current vehicle specification (Type ID) with CONSULT configuration before replacement.
NOTE:
If "Before Replace ECU" of "Read / Write Configuration" can not be used, use the "Manual Configuration" after replacing 3CH CAN gateway.
AFTER REPLACEMENT
CAUTION:
Follow the instructions listed below. Failure to do this may cause malfunctions to the 3CH CAN gateway.:
- When replacing 3CH CAN gateway, you must perform "Read / Write Configuration" or "Manual Configuration" with CONSULT.
- Complete the procedure of "Read / Write Configuration" or "Manual Configuration" in order.
- If incorrect "Read / Write Configuration" or "Manual Configuration", incidents might occur.
- Never perform "Read / Write Configuration" or "Manual Configuration" except for new 3CH CAN gateway.