LEMON Manuals: Even more car manuals for everyone
Home >> Infiniti >> 2018 >> Q70 5.6 Luxe, RWD >> Repair and Diagnosis >> Body & Frame >> Door Locks >> Door Lock (DTC/Circuit Diagnosis) (Except Hybrid) >> DTC/Circuit Diagnosis >> Trunk Lid Open Signal Circuit >> Diagnosis Procedure

Diagnosis Procedure

  1. INSPECTION START 

    Check that which circuit is malfunctioning. Refer to Component Function Check .

    Which circuit is malfunctioning?

    Output signal circuit

    GO TO 2.

    Input signal circuit

    GO TO 4.

  2. CHECK TRUNK LID OPEN REQUEST SIGNAL 
    1. Turn Ignition Switch ON.
    2. Select "TRUNK/BACK DOOR" in "Active Test" mode of "INTELLIGENT KEY" of "BCM" using CONSULT.
    3. Check voltage between Trunk Closure Assembly harness connector and ground when touching "OPEN".

      (+)

      (-)

      CONSULT Active Test condition

      Voltage (V)

      (Approx.)

      Trunk Closure Assembly

      Connector

      Terminal

      T14

      1

      Ground

      TRUNK/GLASS HATCH

      OPEN

      0 -> 12 -> 0

    Is the inspection result normal?

    YES

    GO TO 6.

    NO

    GO TO 3.

  3. CHECK TRUNK LID OPEN REQUEST SIGNAL CIRCUIT 
    1. Turn Ignition Switch OFF.
    2. Disconnect negative battery cable.
    3. Disconnect BCM connector.
    4. Disconnect Trunk Closure Assembly harness connector.
    5. Check continuity between BCM harness connector and Trunk Closure Assembly harness connector.

      BCM

      Trunk Closure Assembly

      Continuity

      Connector

      Terminal

      Connector

      Terminal

      M121

      53

      T14

      1

      Existed

    6. Check continuity between BCM harness connector and ground.

      BCM

      Ground

      Continuity

      Connector

      Terminal

      M121

      53

      Not existed

    Is the inspection result normal?

    YES

    Replace BCM. Refer to Removal and Installation .

    NO

    Repair harness or connector.

  4. CHECK TRUNK LID OPEN/CLOSE STATUS SIGNAL 
    1. Check voltage between BCM harness connector and ground under the following conditions.

      (+)

      (-)

      Condition

      Voltage (V)

      (Approx.)

      BCM

      Connector

      Terminal

      M121

      42

      Ground

      Trunk lid

      Open

      0

      Closed

      12

    Is the inspection result normal?

    YES

    GO TO 6.

    NO

    GO TO 5.

  5. CHECK TRUNK LID OPEN/CLOSE STATUS SIGNAL CIRCUIT 
    1. Turn Ignition Switch OFF.
    2. Disconnect negative battery cable.
    3. Disconnect BCM connector.
    4. Disconnect Trunk Closure Assembly harness connector.
    5. Check continuity between BCM harness connector and Trunk Closure Assembly harness connector.

      BCM

      Trunk Closure Assembly

      Continuity

      Connector

      Terminal

      Connector

      Terminal

      M121

      42

      T14

      5

      Existed

    6. Check continuity between BCM harness connector and ground.

      BCM

      Ground

      Continuity

      Connector

      Terminal

      M121

      42

      Not existed

    Is the inspection result normal?

    YES

    Replace Trunk Closure Assembly. Refer to Removal and Installation .

    NO

    Repair harness or connector.

  6. CHECK INTERMITTENT INCIDENT 

    Refer to Intermittent Incident .

    INSPECTION END