C0049 - 15, C0049 - 7B
- CHECK POWER SUPPLY VOLTAGE OF BCM
Check power supply and ground circuit of BCM. Refer to DIAGNOSIS PROCEDURE .
Is the inspection result normal?
YES
GO TO STEP 2 .
NO
Repair or replace the malfunctioning parts.
- CHECK BRAKE FLUID LEVEL
- Turn the ignition switch OFF.
- Check the brake fluid level. Refer to INSPECTION .
Is the inspection result normal?
YES
GO TO STEP 4 .
NO
Refill the brake fluid, and GO TO STEP 3.
- Refer to REFILLING .
- PERFORM DTC CONFIRMATION PROCEDURE AGAIN
Perform DTC confirmation procedure again. Refer to DTC DESCRIPTION .
Is DTC C0049 detected again?
YES
GO TO STEP 4 .
NO
INSPECTION END
- check brake fluid level switch
- Turn the ignition switch off.
- Disconnect the brake fluid level switch harness connector.
- Connect decade resistor to the brake fluid level switch connector.
- Check resistance brake fluid level switch.
Check result Specified value 10 kΩ OK 1 Ω Not OK
Is the inspection result normal?
YES
GO TO STEP 5 .
NO
Replace brake master cylinder. Refer to REMOVAL AND INSTALLATION .
- check brake fluid level switch circuit
- Disconnect the BCM harness connector.
- Check the continuity between brake fluid level switch harness connector and BCM harness connector.
Brake fluid level switch BCM Continuity Connector Terminal Connector Terminal E10 1 E16 164 Existed 2 E15 138 Existed - Check the continuity between brake fluid level switch harness connector and ground.
Brake fluid level switch - Continuity Connector Terminal E10 2 Ground Not existed
Is the inspection result normal?
YES
Replace brake master cylinder. Refer to REMOVAL AND INSTALLATION .
NO
Repair harness or connector.