Diagnosis Procedure
- CHECK HARNESS CONNECTOR CONNECTION
Check the following harness connector for disconnection or looseness.
- CAN potential distributor electrical connector (powertrain)
- ECM
Is the inspection result normal?
YES
GO TO STEP 2 .
NO
Securely connect the harness connectors.
- CHECK POWER SUPPLY AND GROUND CIRCUIT
Check power supply and ground circuit for ECM. Refer to DIAGNOSIS PROCEDURE .
Is the inspection result normal?
YES
GO TO STEP 3 .
NO
Repair or replace the malfunctioning part.
- CHECK CIRCUIT (SHORT TO BATTERY)
- Turn ignition switch OFF.
- Disconnect the following unit connectors.
- CAN potential distributor electrical connector (powertrain)
- ECM
- Check voltage between CAN potential distributor electrical connector (powertrain) harness connector and ground.
Terminals Voltage
(Approx.)+ - CAN potential distributor electrical connector (powertrain) Ground Connector Terminal E98 8 - 0 V 9
Is the inspection result normal?
YES
GO TO STEP 4 .
NO
Repair or replace harness.
- CHECK CIRCUIT (SHORT TO GROUND)
Check continuity between CAN potential distributor electrical connector (powertrain) harness connector and ground.
CAN potential distributor electrical connector (powertrain) Ground Continuity Connector Terminal E98 8 - Not existed 9 Is the inspection result normal?
YES
GO TO STEP 5 .
NO
Repair or replace harness.
- CHECK CIRCUIT (SHORT WITH CAN-H AND CAN-L)
Check continuity between CAN potential distributor electrical connector (powertrain) harness connector terminals.
CAN potential distributor electrical connector (powertrain) Continuity Connector Terminal Connector Terminal E98 8 E98 9 Not existed Is the inspection result normal?
YES
GO TO STEP 6 .
NO
Repair or replace harness.
- CHECK CIRCUIT (OPEN)
Check continuity between the following unit harness connectors.
- CAN potential distributor electrical connector (powertrain)
- ECMCAN POTENTIAL DISTRIBUTOR ELECTRICAL CONNECTOR (POWERTRAIN) - ECM
CAN potential distributor electrical connector (powertrain) ECM Continuity Connector Terminal Connector Terminal E98 8 E48 138 Existed 9 151
Is the inspection result normal?
YES
INSPECTION END
NO
Repair or replace harness.