Diagnosis Procedure
- CHECK HARNESS CONNECTOR CONNECTION
Check the following harness connector for disconnection or looseness.
- CAN potential distributor electrical connector (body)
- Combination meter
Is the inspection result normal?
YES
GO TO STEP 2 .
NO
Securely connect the harness connectors.
- CHECK POWER SUPPLY AND GROUND CIRCUIT
Check power supply and ground circuit for combination meter. Refer to DIAGNOSIS PROCEDURE .
Is the inspection result normal?
YES
GO TO STEP 3 .
NO
Repair or replace the malfunctioning part.
- CHECK CIRCUIT (SHORT TO BATTERY)
- Turn ignition switch OFF.
- Disconnect the following unit connectors.
- CAN potential distributor electrical connector (body)
- Combination meter
- Check voltage between CAN potential distributor electrical connector (body) harness connector and ground.
Terminals Voltage
(Approx.)+ - CAN potential distributor electrical connector (body) Ground Connector Terminal M19 1 - 0 V 2
Is the inspection result normal?
YES
GO TO STEP 4 .
NO
Repair or replace harness.
- CHECK CIRCUIT (SHORT TO GROUND)
Check continuity between CAN potential distributor electrical connector (body) harness connector and ground.
CAN potential distributor electrical connector (body) Ground Continuity Connector Terminal M19 1 - Not existed 2 Is the inspection result normal?
YES
GO TO STEP 5 .
NO
Repair or replace harness.
- CHECK CIRCUIT (SHORT WITH CAN-H AND CAN-L)
Check continuity between CAN potential distributor electrical connector (body) harness connector terminals.
CAN potential distributor electrical connector (body) Continuity Connector Terminal Connector Terminal M19 1 M19 2 Not existed Is the inspection result normal?
YES
GO TO STEP 6 .
NO
Repair or replace harness.
- CHECK CIRCUIT (OPEN)
Check continuity between the following unit harness connectors.
- CAN potential distributor electrical connector (body)
- Combination meterCAN POTENTIAL DISTRIBUTOR ELECTRICAL CONNECTOR (BODY) - COMBINATION METER
CAN potential distributor electrical connector (body) Combination meter Continuity Connector Terminal Connector Terminal M19 1 M32 18 Existed 2 17
Is the inspection result normal?
YES
INSPECTION END
NO
Repair or replace harness.