Diagnosis Procedure
- CHECK FUSE
Check for blown fuses.
Power source Fuse No. Battery 88 Is the inspection result normal?
YES
GO TO STEP 2.
NO
Be sure to eliminate cause of malfunction before installing new fuse.
- CHECK POWER SUPPLY CIRCUIT
Check voltage between combination meter harness connector and ground.
Probe Ignition switch position Voltage
(Approx.)+ - Combination meter Connector Terminal M32 4 Ground OFF Battery voltage Is the inspection result normal?
YES
GO TO STEP 3.
NO
Check harness between combination meter and fuse.
- CHECK GROUND CIRCUIT
- Turn ignition switch OFF.
- Disconnect combination meter connector.
- Check continuity between combination meter harness connector and ground.
Combination meter Ground Continuity Connector Terminal M32 1 Existed
Is the inspection result normal?
YES
Check intermittent incident. Refer to INTERMITTENT INCIDENT .
NO
Repair harness or connector.