Component Function Check
WARNING: This page is about a different variant/trim than selected.
- CHECK COMBINATION METER INPUT SIGNAL
- Turn ignition switch ON.
- Measure voltage between the following terminals of the combination meter.
Terminals Condition Voltage
(Approx.)Combination meter Ground Connector (+) M57 24 Washer level switch ON 0 V Washer level switch OFF 12 V
Is the inspection result normal?
YES
INSPECTION END
NO
Refer to DIAGNOSIS PROCEDURE .