LEMON Manuals: Even more car manuals for everyone
Home >> Infiniti >> 2016 >> Q50 Base, RWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 169 (Automatic Transmission (Symptom Diagnosis & Removal And Installation) (Except Hybrid)) >> Periodic Maintenance >> A/T Fluid >> Adjustment

A/T Fluid: Adjustment

WARNING: This page is about a different car, the 2018 Infiniti Q50. However, it is still accessible from the selected car via links, so may be relevant.

Recommended fluid and fluid capacity

: Refer to Fluids and Lubricants .

CAUTION:
  • Use only recommended ATF. Never mix with other ATF.
  • Using ATF other than recommended ATF will cause deterioration in driveability and A/T durability, and may damage the A/T, which is not covered by the INFINITI new vehicle limited warranty.
  • When filling ATF, be careful not to scatter heat generating parts such as exhaust.
  • Always maintain the ATF temperature within between 35 deg.C (95 deg.F) and 45 deg.C (113 deg.F) while checking with CONSULT when the ATF level adjustment is performed.
  1. Install the O-ring (315268E000) (A) to the charging pipe (310811EA5A) (B).
    GNSJSDIA1334Z-334Courtesy of NISSAN NORTH AMERICA, INC.
  2. Start the engine.
  3. Make the ATF temperature approximately 40 deg.C (104 deg.F).
    NOTE: The ATF level is greatly affected by the temperature. Always check the ATF temperature on "ATF TEMP 1" of "Data Monitor" using CONSULT.
  4. Park vehicle on level surface and set parking brake.
  5. Shift the selector lever through each gear position. Leave selector lever in "P" position.
  6. Lift up the vehicle.
  7. Check the ATF leakage from transmission.
  8. Remove overflow plug from oil pan.
  9. Install the charging pipe (A) to the overflow plug hole.
    GNSJSDIA1335Z-335Courtesy of NISSAN NORTH AMERICA, INC.
    CAUTION: Tighten the charging pipe by hand.
  10. Install the bucket pump hose (B) to the charging pipe.
    CAUTION: Insert the bucket pump hose all the way to the end of the charging pipe.
  11. Fill approximately 0.5 liters (1/2 US qt, 1/2 lmp qt) of the ATF.
  12. Check that the ATF leaks when removing the charging pipe and the bucket pump hose. If the ATF does not leak, refill the ATF.
  13. When the ATF starts to drip, tighten the overflow plug to the oil pan to the specified torque. Refer to Exploded View .
    CAUTION: Never reuse overflow plug.