Diagnosis Procedure
- CHECK AUTOMATIC BACK DOOR CLOSE SWITCH INPUT SIGNAL
- Turn ignition switch OFF.
- Disconnect automatic back door close switch connector.
- Check voltage between automatic back door close switch harness connector and ground.
(+) (-) Voltage
(Approx.)Automatic back door close switch Connector Terminal D158 1 Ground Battery voltage
Is the inspection result normal?
YES
GO TO STEP 3 .
NO
GO TO STEP 2 .
- CHECK AUTOMATIC BACK DOOR CLOSE SWITCH CIRCUIT
- Disconnect automatic back door control module connector.
- Check continuity between automatic back door control module harness connector and automatic back door close switch harness connector.
Automatic back door control module Automatic back door close switch Continuity Connector Terminal Connector Terminal B26 4 D158 1 Existed - Check continuity between automatic back door control module harness connector and ground.
Automatic back door control module Ground Continuity Connector Terminal B26 4 Not existed
Is the inspection result normal?
YES
Replace automatic back door control module. Refer to REMOVAL AND INSTALLATION .
NO
Repair or replace harness.
- CHECK AUTOMATIC BACK DOOR CLOSE SWITCH GROUND CIRCUIT
Check continuity between automatic back door close switch harness connector and ground.
Automatic back door close switch Ground Continuity Connector Terminal D158 2 Existed Is the inspection result normal?
YES
GO TO STEP 4 .
NO
Repair or replace harness.
- CHECK AUTOMATIC BACK DOOR CLOSE SWITCH
Refer to COMPONENT INSPECTION .
Is the inspection result normal?
YES
GO TO STEP 5 .
NO
Replace automatic back door close switch.
- CHECK INTERMITTENT INCIDENT
Refer to INTERMITTENT INCIDENT .
INSPECTION END