Component Inspection
- CHECK AUTOMATIC BACK DOOR CLOSE SWITCH
- Turn ignition switch OFF.
- Disconnect automatic back door close switch connector.
- Check continuity between automatic back door close switch terminals.
Automatic back door close switch Condition Continuity Terminal 1 2 Automatic back door close switch Pressed Existed Released Not existed Is the inspection result normal?
YES
INSPECTION END
NO
Replace automatic back door close switch.