LEMON Manuals: Even more car manuals for everyone
Home >> Infiniti >> 2015 >> QX60 Base, FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 92 (Automatic Drive Positioner (DTC/Circuit Diagnosis) (Except Hybrid)) >> DTC/Circuit Diagnosis >> Door Mirror Motor >> Diagnosis Procedure

Diagnosis Procedure

WARNING: This page is about a different car, the 2016 Infiniti QX60. However, it is still accessible from the selected car via links, so may be relevant.

Regarding Wiring Diagram information, refer to WIRING DIAGRAM .

  1. CHECK DOOR MIRROR MOTOR INPUT SIGNAL

    1. Turn ignition switch ON.
    2. Check voltage between door mirror connector and ground.
      (+) (+)-) Door mirror remote control switch condition Voltage (V)
      (Approx.)
      Door mirror
      Connector Terminal
      D6 (LH)
      D116 (RH)
      (with around view monitor)
      12 Ground UP Battery voltage
      Other than above 0
      11 LEFT Battery voltage
      Other than above 0
      10 DOWN / RIGHT Battery voltage
      Other than above 0
      D4 (LH)
      D107 (RH)
      (without around view monitor)
      8 Ground UP Battery voltage
      Other than above 0
      9 LEFT Battery voltage
      Other than above 0
      10 DOWN / RIGHT Battery voltage
      Other than above 0

    Is the inspection result normal?

    YES 

    Refer to COMPONENT INSPECTION .

    NO 

    GO TO STEP 2. 

  2. CHECK HARNESS CONTINUITY

    1. Turn ignition switch OFF.
    2. Disconnect automatic drive positioner control unit and door mirror.
    3. Check continuity between automatic drive positioner control unit connector and door mirror connector.

      Door mirror LH

      Automatic drive positioner control unit Door mirror LH connector Continuity
      Connector Terminal Connector Terminal
      M33 12 D6
      (with around view monitor)
      10 Yes
      23 12
      24 11
      M33 12 D4
      (without around view monitor)
      10 Yes
      23 8
      24 9

      Door mirror RH

      Automatic drive positioner control unit Door mirror RH Continuity
      Connector Terminal Connector Terminal
      M33 10 D116
      (with around view monitor)
      12 Yes
      11 11
      22 10
      M33 10 D107
      (without around view monitor)
      8 Yes
      11 9
      22 10
    4. Check continuity between automatic drive positioner control unit connector and ground.

      Door mirror LH

      Automatic drive positioner control unit Ground Continuity
      Connector Terminal
      M33 12 No
      23
      24

      Door mirror RH

      Automatic drive positioner control unit Ground Continuity
      Connector Terminal
      M33 10 No
      11
      22

    Is the inspection result normal?

    YES 

    GO TO STEP 3. 

    NO 

    Repair or replace harness.

  3. CHECK AUTOMATIC DRIVE POSITIONER CONTROL UNIT OUTPUT SIGNAL

    1. Connect automatic drive positioner control unit.
    2. Turn ignition switch ON.
    3. Check voltage between automatic drive positioner control unit connector and ground.

      Door mirror LH

      (+) (-) Mirror switch condition Voltage (V)
      (Approx.)
      Automatic drive positioner control unit
      Connector Terminal
      M33 12 Ground DOWN / RIGHT Battery voltage
      Other than above 0
      23 UP Battery voltage
      Other than above 0
      24 LEFT Battery voltage
      Other than above 0

      Door mirror RH

      (+) (-) Mirror switch condition Voltage (V)
      (Approx.)
      Automatic drive positioner control unit
      Connector Terminal
      M33 10 Ground UP Battery voltage
      Other than above 0
      11 LEFT Battery voltage
      Other than above 0
      22 DOWN / RIGHT Battery voltage
      Other than above 0

    Is the inspection result normal?

    YES 

    GO TO 4.

    NO 

    Replace automatic drive positioner control unit. Refer to REMOVAL AND INSTALLATION .

  4. CHECK DOOR MIRROR MOTOR

    Check door mirror motor.

    Refer to COMPONENT INSPECTION .

    Is the inspection result normal?

    YES 

    Refer to INTERMITTENT INCIDENT .

    NO 

    Replace door mirror actuator. Refer to REMOVAL AND INSTALLATION .