LEMON Manuals: Even more car manuals for everyone
Home >> Infiniti >> 2015 >> QX60 Base, FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 79 (Brake Control System (DTC/Circuit Diagnosis) (Without ICC) (Except Hybrid)) >> DTC/Circuit Diagnosis >> VDC Off Switch >> Diagnosis Procedure

Diagnosis Procedure

WARNING: This page is about a different car, the 2016 Infiniti QX60. However, it is still accessible from the selected car via links, so may be relevant.

Regarding Wiring Diagram information, refer to WIRING DIAGRAM .

  1. CONNECTOR INSPECTION

    1. Turn ignition switch OFF.
    2. Disconnect ABS actuator and electric unit (control unit) connector E125 and VDC OFF switch connector M71.
    3. Check connectors and terminals for deformation, disconnection, looseness or damage.

    Is the inspection result normal?

    YES 

    GO TO STEP 2  .

    NO 

    Repair or replace as necessary.

  2. CHECK VDC OFF SWITCH

    Check VDC OFF switch. Refer to COMPONENT INSPECTION .

    Is the inspection result normal?

    YES 

    GO TO STEP 3  .

    NO 

    Replace VDC OFF switch.

  3. CHECK VDC OFF SWITCH SIGNAL

    G-20 With CONSULT.

    1. Connect ABS actuator and electric unit (control unit) connector E125 and VDC OFF switch connector M71.
    2. Turn ignition switch ON.
    3. In "DATA MONITOR" select "OFF SW" and check VDC OFF switch signal.
      Condition DATA MONITOR
      VDC OFF switch is pressed and released On
      VDC OFF switch is pressed and released again Off

    Is the inspection result normal?

    YES 

    Refer to WORK FLOW .

    NO 

    GO TO STEP 4  .

  4. CHECK VDC OFF SWITCH CIRCUIT

    1. Turn ignition switch OFF.
    2. Disconnect ABS actuator and electric unit (control unit) connector E125 and VDC OFF switch connector M71.
    3. Check continuity between ABS actuator and electric unit (control unit) connector E125 terminal 30 and VDC OFF switch connector M71 terminal 1.
      ABS actuator and electric unit (control unit) VDC OFF switch Continuity
      Connector Terminal Connector Terminal
      E125 9 M71 1 Yes
    4. Check continuity between ABS actuator and electric unit (control unit) connector terminal E125 terminal 30 and ground.
      ABS actuator and electric unit (control unit) - Continuity
      Connector Terminal
      E125 9 Ground No

    Is the inspection result normal?

    YES 

    GO TO STEP 5  .

    NO 

    Repair or replace malfunctioning components.

  5. CHECK VDC OFF SWITCH GROUND CIRCUIT

    Check continuity between VDC OFF switch connector M71 terminal 2 and ground.

    VDC OFF switch - Continuity
    Connector Terminal
    M71 2 Ground Yes

    Is the inspection result normal?

    YES 

    Replace ABS actuator and electric unit (control unit). Refer to REMOVAL AND INSTALLATION .

    NO 

    Repair or replace malfunctioning components.