Diagnosis Procedure
WARNING: This page is about a different car, the 2016 Infiniti QX60. However, it is still accessible from the selected car via links, so may be relevant.
Regarding Wiring Diagram information, refer to WIRING DIAGRAM .
- CONNECTOR INSPECTION
- Turn ignition switch OFF.
- Disconnect ABS actuator and electric unit (control unit) connector E125 and VDC OFF switch connector M71.
- Check connectors and terminals for deformation, disconnection, looseness or damage.
Is the inspection result normal?
YES
GO TO STEP 2 .
NO
Repair or replace as necessary.
- CHECK VDC OFF SWITCH
Check VDC OFF switch. Refer to COMPONENT INSPECTION .
Is the inspection result normal?
YES
GO TO STEP 3 .
NO
Replace VDC OFF switch.
- CHECK VDC OFF SWITCH SIGNAL
With CONSULT.
- Connect ABS actuator and electric unit (control unit) connector E125 and VDC OFF switch connector M71.
- Turn ignition switch ON.
- In "DATA MONITOR" select "OFF SW" and check VDC OFF switch signal.
Condition DATA MONITOR VDC OFF switch is pressed and released On VDC OFF switch is pressed and released again Off
Is the inspection result normal?
YES
Refer to WORK FLOW .
NO
GO TO STEP 4 .
- CHECK VDC OFF SWITCH CIRCUIT
- Turn ignition switch OFF.
- Disconnect ABS actuator and electric unit (control unit) connector E125 and VDC OFF switch connector M71.
- Check continuity between ABS actuator and electric unit (control unit) connector E125 terminal 30 and VDC OFF switch connector M71 terminal 1.
ABS actuator and electric unit (control unit) VDC OFF switch Continuity Connector Terminal Connector Terminal E125 9 M71 1 Yes - Check continuity between ABS actuator and electric unit (control unit) connector terminal E125 terminal 30 and ground.
ABS actuator and electric unit (control unit) - Continuity Connector Terminal E125 9 Ground No
Is the inspection result normal?
YES
GO TO STEP 5 .
NO
Repair or replace malfunctioning components.
- CHECK VDC OFF SWITCH GROUND CIRCUIT
Check continuity between VDC OFF switch connector M71 terminal 2 and ground.
VDC OFF switch - Continuity Connector Terminal M71 2 Ground Yes Is the inspection result normal?
YES
Replace ABS actuator and electric unit (control unit). Refer to REMOVAL AND INSTALLATION .
NO
Repair or replace malfunctioning components.