Diagnosis Procedure
Regarding Wiring Diagram information, refer to WIRING DIAGRAM .
- CALIBRATION OF AUTOMATIC BACK DOOR POSITION INFORMATION
- Perform initialization setting of automatic back door position information.
Refer to WORK PROCEDURE .
- Erase DTC, and then repeat "PERFORM DTC CONFIRMATION PROCEDURE".
Is DTC detected?
YES
GO TO STEP 2 .
NO
Inspection End.
- Perform initialization setting of automatic back door position information.
- CHECK INSTALLATION OF BACK DOOR ASSEMBLY
- Check that back door assembly is installed normally.
Refer to ADJUSTMENT .
- Check back door assembly mechanism deformation, looseness, rattle, interference with other parts, and pinched foreign materials.
Is the inspection result normal?
YES
GO TO STEP 3 .
NO
Repair or replace the malfunctioning parts.
- Check that back door assembly is installed normally.
- CHECK ENCODER SIGNAL
- Select "AUTOMATIC BACK DOOR CONTROL MODULE" using CONSULT.
- Select "SPINDLE LH ENCODER A" and "SPINDLE LH ENCODER B" in "DATA MONITOR" mode.
- Check that the function operates normally according to the following conditions.
Monitor item Condition Status SPINDLE LH ENCODER A Back door Moving (auto or manual) HI ==> LO When stopped HI or LO SPINDLE LH ENCODER B Moving (auto or manual) HI ==> LO When stopped HI or LO
Is the inspection result normal?
YES
Replace automatic back door control module. Refer to REMOVAL AND INSTALLATION .
NO
GO TO STEP 4 .
- CHECK ENCODER POWER SUPPLY
- Turn ignition switch OFF.
- Disconnect spindle unit LH connector.
- Turn ignition switch ON.
- Check voltage between spindle unit LH harness connector and ground.
(+) (-) Voltage
(Approx.)Spindle unit LH Connector Terminal B70 8 Ground Battery voltage
Is the inspection result normal?
YES
GO TO STEP 6 .
NO
GO TO STEP 5 .
- CHECK ENCODER POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect automatic back door control module connector.
- Check continuity between automatic back door control module harness connector and spindle unit LH harness connector.
Automatic back door control module Spindle unit LH Continuity Connector Terminal Connector Terminal B55 19 B70 8 Yes - Check continuity between automatic back door control module harness connector and ground.
Automatic back door control module Ground Continuity Connector Terminal B55 19 No
Is the inspection result normal?
YES
Replace automatic back door control module. Refer to REMOVAL AND INSTALLATION .
NO
Repair or replace harness.
- CHECK ENCODER SIGNAL CIRCUITS
- Turn ignition switch OFF.
- Disconnect automatic back door control module connector.
- Check continuity between automatic back door control module harness connector and spindle unit LH harness connector.
Automatic back door control module Spindle unit LH Continuity Connector Terminal Connector Terminal B55 6 B70 3 Yes 7 10 - Check continuity between automatic back door control module harness connector and ground.
Automatic back door control module Ground Continuity Connector Terminal B55 6 No 7
Is the inspection result normal?
YES
GO TO STEP 7 .
NO
Repair or replace harness.
- CHECK ENCODER GROUND CIRCUIT
- Connect automatic back door control module and spindle unit LH connector.
- Check continuity between automatic back door control module harness connector and ground.
Automatic back door control module Ground Voltage
(Approx.)Connector Terminal B55 21 0 V
Is the inspection result normal?
YES
Replace spindle unit LH. Refer to REMOVAL AND INSTALLATION .
NO
Repair or replace harness.