Diagnosis Procedure
- CHECK TRUNK ROOM LAMP SWITCH INPUT SIGNAL
- Turn ignition switch OFF.
- Disconnect trunk room lamp switch connector.
- Check signal between trunk room lamp switch harness connector and ground using oscilloscope.
(+) (-) Signal
(Reference value)Trunk room lamp switch Connector Terminal B306 2 Ground
Is the inspection result normal?
YES
GO TO STEP 3 .
NO
GO TO STEP 2 .
- CHECK TRUNK ROOM LAMP SWITCH CIRCUIT
- Disconnect BCM connector, trunk closure control unit connector and retractable hard top control unit connector.
- Check continuity between BCM harness connector and trunk room lamp switch harness connector.
BCM Trunk room lamp switch Continuity Connector Terminal Connector Terminal M121 50 B306 2 Existed - Check continuity between BCM harness connector and ground.
BCM Ground Continuity Connector Terminal M121 50 Not existed
Is the inspection result normal?
YES
Replace BCM. Refer to REMOVAL AND INSTALLATION .
NO
Repair harness or connector.
- CHECK TRUNK ROOM LAMP SWITCH GROUND CIRCUIT
- Disconnect trunk lid opener actuator connector.
- Check continuity between retractable hard top control unit harness connector and trunk room lamp switch harness connector.
Retractable hard top control unit Trunk room lamp switch Continuity Connector Terminal Connector Terminal B83 52 B306 1 Existed - Check continuity between retractable hard top control unit harness connector and ground.
Retractable hard top control unit Ground Continuity Connector Terminal B83 52 Not existed
Is the inspection result normal?
YES
GO TO STEP 4 .
NO
Repair or replace harness.
- CHECK RETRACTABLE HARD TOP CONTROL UNIT POWER SUPPLY AND GROUND CIRCUIT
Refer to DIAGNOSIS PROCEDURE .
Is the inspection result normal?
YES
GO TO STEP 5 .
NO
Repair or replace the malfunctioning parts.
- CHECK TRUNK ROOM LAMP SWITCH GROUND
- Connect retractable hard top control unit connector.
- Check continuity between retractable hard top control unit harness connector and ground.
Retractable hard top control unit Ground Continuity Connector Terminal B83 52 Existed
Is the inspection result normal?
YES
GO TO STEP 6 .
NO
Replace retractable hard top control unit. Refer to REMOVAL AND INSTALLATION .
- CHECK TRUNK ROOM LAMP SWITCH
Refer to COMPONENT INSPECTION .
Is the inspection result normal?
YES
GO TO STEP 7 .
NO
Replace trunk room lamp switch (trunk lid lock assembly). Refer to REMOVAL AND INSTALLATION .
- CHECK INTERMITTENT INCIDENT
Refer to INTERMITTENT INCIDENT .
INSPECTION END