Component Inspection
- CHECK TRUNK ROOM LAMP SWITCH
- Turn ignition switch OFF.
- Disconnect trunk room lamp switch connector.
- Check continuity between trunk room lamp switch terminals.
Trunk room lamp switch Condition Continuity Terminal 1 2 Trunk lid lock assembly Unlocked Existed Locked Not existed
Is the inspection result normal?
YES
INSPECTION END
NO
Replace trunk room lamp switch (trunk lid lock assembly). Refer to REMOVAL AND INSTALLATION .