Diagnosis Procedure
- CHECK COMBINATION METER POWER SUPPLY AND GROUND CIRCUIT
Check combination meter power supply and ground circuit. Refer to DIAGNOSIS PROCEDURE .
Is the inspection result normal?
YES
GO TO STEP 2 .
NO
Repair or replace malfunctioning parts.
- CHECK AV COMMUNICATION CIRCUIT
- Turn ignition switch OFF.
- Disconnect display control unit harness connector and combination meter harness connector.
- Check the continuity between display control unit harness connector and combination meter harness connector.
Display control unit Combination meter Continuity Connector Terminal Connector Terminal M100 16 M58 48 Existed 28 47
Is the inspection result normal?
YES
Replace combination meter. Refer to REMOVAL AND INSTALLATION .
NO
Repair or replace malfunctioning parts.