Diagnosis Procedure
- CHECK FUSE
Check for blown fuses.
Power source Fuse No. Battery 6 Ignition switch ON or START 11 Ignition switch ON or ACC 1 Is the inspection result normal?
YES
GO TO STEP 2.
NO
Be sure to eliminate cause of malfunction before installing new fuse.
- CHECK POWER SUPPLY CIRCUIT
Check voltage between combination meter harness connector and ground.
Terminals Ignition switch position Voltage
(Approx.)(+) (-) Combination meter Ground Connector Terminal M58 45 OFF Battery voltage 46 ON M57 14 ACC Is the inspection result normal?
YES
GO TO STEP 3.
NO
Check harness between combination meter and fuse.
- CHECK GROUND CIRCUIT
- Turn ignition switch OFF.
- Disconnect combination meter connector.
- Check continuity between combination meter harness connector and ground.
Combination meter Ground Continuity Connector Terminal M57 1 Existed M58 52
Is the inspection result normal?
YES
INSPECTION END
NO
Repair harness or connector.