COMBINATION METER: Diagnosis Procedure
Regarding Wiring Diagram information, refer to "WIRING DIAGRAM - WITH AUTOMATIC DRIVE POSITIONER " or "WIRING DIAGRAM - WITHOUT AUTOMATIC DRIVE POSITIONER ".
- CHECK FUSES
Check for blown combination meter fuses.
Unit Power source Fuse No. Combination meter Battery 13 65 Ignition switch ON or START 31 Is the inspection result normal?
YES: GO TO 2
NO: Replace the fuse after repairing the affected circuit.
- POWER SUPPLY CIRCUIT CHECK
- Disconnect combination meter connector.
- Check voltage between combination meter harness connector M24 terminals 5, 21, 22 and ground.
Terminals Ignition switch position (+) (-) OFF ACC ON START Connector Terminal M24 22 Ground Battery voltage Battery voltage Battery voltage Battery voltage 21 0V 0V Battery voltage Battery voltage 5 0V Battery voltage Battery voltage 0V Is the inspection result normal?
YES: GO TO 3
NO: Repair or replace harness or connectors.
- GROUND CIRCUIT CHECK