Diagnosis Procedure
- CHECK THE OPERATION
Check automatic back door main switch function.
NOTE: When the main switch is OFF, the automatic back door operation is not available by back door opener switch and automatic back door close switch.Is the inspection result normal?
YES: Automatic back door system is normal.
NO: GO TO 2.
- CHECK AUTOMATIC BACK DOOR MAIN SWITCH
Check automatic back door main switch.
Refer to "COMPONENT FUNCTION CHECK ".
Is the inspection result normal?
YES: GO TO 3.
NO: Repair or replace the malfunctioning parts.
- REPLACE AUTOMATIC BACK DOOR CONTROL MODULE
- Replace automatic back door control module. Refer to "REMOVAL AND INSTALLATION ".
- Confirm the operation after replacement.
Is the result normal?
YES: Inspection End.
NO: Check intermittent incident. Refer to "INTERMITTENT INCIDENT ".