LEMON Manuals: Even more car manuals for everyone
Home >> Infiniti >> 2013 >> FX37 Base, RWD >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Heater & Air Conditioning Control System (Automatic Air Conditioning) >> Symptom Diagnosis >> Insufficient Cooling >> Inspection procedure

Inspection procedure

  1. CHECK WITH A GAUGE OF RECOVERY/RECYCLING RECHARGING EQUIPMENT 

    Connect the recovery/recycling recharging equipment to the vehicle and perform the pressure inspection with the gauge.

    Is there refrigerant? 

    YES: GO TO 2.

    NO-1: Check for refrigerant leakages with the refrigerant leakage detecting fluorescent leak detector. Refer to "INSPECTION " (VQ37VHR) or "INSPECTION " (VK50VE).

    NO-2: GO TO 2 after repairing or replacing the parts according to the inspection results.

  2. CHECK CHARGED REFRIGERANT AMOUNT 
    1. Connect recovery/recycling recharging equipment to the vehicle and discharge the refrigerant. Refer to "COLLECTION AND CHARGE " (VQ37VHR) or "COLLECTION AND CHARGE " (VK50VE).
    2. Recharge with the proper amount of refrigerant. Refer to "COLLECTION AND CHARGE " (VQ37VHR) or "COLLECTION AND CHARGE " (VK50VE).
    3. Perform the inspection with the refrigerant leakage detecting fluorescent leak detector. Refer to "INSPECTION " (VQ37VHR) or "INSPECTION " (VK50VE).

      Is the inspection result normal? 

      YES: GO TO 3.

      NO: Refill the refrigerant and repair or replace the parts according to the inspection results.

  3. PERFORM THE PERFORMANCE TEST 

    Connect recovery/recycling recharging equipment to the vehicle and perform the performance test. Refer to "PERFORMANCE CHART " (VQ37VHR) or "PERFORMANCE CHART " (VK50VE).

    Is the inspection result normal? 

    YES: GO TO 4.

    NO: Perform the diagnosis with the gauge pressure. Refer to "TROUBLE DIAGNOSIS FOR UNUSUAL PRESSURE " (VQ37VHR) or "TROUBLE DIAGNOSIS FOR UNUSUAL PRESSURE " (VK50VE).

  4. CHECK SETTING OF TEMPERATURE SETTING TRIMMER 

    Check the setting of temperature setting trimmer. Refer to "WITHOUT ACCS: TEMPERATURE SETTING TRIMMER " (WITHOUT ACCS) or "WITH ACCS: TEMPERATURE SETTING TRIMMER " (WITH ACCS).

    1. Check that the temperature setting trimmer is set to "+ direction".
      NOTE: The control temperature can be set with the setting of temperature setting trimmer.
    2. Set temperature control dial to "0".

      Are the symptoms solved? 

      YES: INSPECTION END

      NO: GO TO 5.

  5. PERFORM SELF-DIAGNOSIS 

    Perform self-diagnosis function. Refer to "WITHOUT ACCS: DIAGNOSIS DESCRIPTION " (WITHOUT ACCS) or "WITH ACCS: DIAGNOSIS DESCRIPTION " (WITH ACCS).

    Is the inspection result normal? 

    YES: GO TO 6.

    NO: Repair or replace parts according to the inspection results.

  6. CHECK DRIVE BELT 

    Check tension of the drive belt. Refer to "CHECKING " (VQ37VHR) or "CHECKING " (VK50VE).

    Is the inspection result normal? 

    YES: GO TO 7.

    NO: Adjust or replace drive belt.

  7. CHECK AIR LEAKAGE FROM DUCT 

    Check duct and nozzle, etc. of A/C system for air leakage.

    Is the inspection result normal? 

    YES: GO TO 8.

    NO: Repair or replace parts according to the inspection results.

  8. CHECK ECV 

    Perform the ECV diagnosis procedure. Refer to "DIAGNOSIS PROCEDURE ".

    Is the inspection result normal? 

    YES: Replace the unified meter and A/C amp.

    NO: Replace the compressor.